Instructions

Engineering Submittal
Instinct Floor Standing 155 Solo
Date: 7/27/21 1 2021-03 Instinct FSB 155 Submittal
Instinct Floor Standing 155 Solo Features
Heavy duty construction for floor standing installation
Approved for zero clearance to combustibles
2” PVC, CPVC, PP venting up to 28 equivalent feet
3” PVC, CPVC, PP, or AL29-4C venting up to 100
equivalent feet
Left or Right side optional boiler connections
Left, Right, Top, or Back gas connections
10 year limited warranty on heat exchanger
Up to 6 year limited warranty on parts, except igniter
Up to 3 year labor allowance
Approvals
95% AFUE Efficiency
ENERGY STAR Qualified
ANSI Z21.13 and CSA 4.9 Boiler Standards Compliance
ASME Boiler Certification ASME “H” Stamp
SCAQMD Rule 1146.2 Low NOx Certification
Stainless Steel Fire Tube Heat Exchanger
439 Stainless Steel heat exchanger construction for
corrosion resistance
High water content provides stable temperature
control
Self cleaning flue ways reduce maintenance
Suitable for use with propylene glycol up to 50%
concentration
CTRLMax Control System
Graphical display with 5 navigation buttons
EZ Setup allows quick and easy boiler settings
adjustment
Flexible configuration of 4 circulator outputs for
custom applications
Outdoor temperature reset to maximize efficiency
Accepts two space heating call inputs with
independent outdoor reset curves
Domestic hot water priority with optional time-out
Integrated cascade control for up to 6 Instinct boilers
0-10 VDC Modulation input
Modbus building management system (BMS)
interface, LonWorks® and BACnet® interface optional
Adjustable warm weather shutdown
Adjustable boiler freeze protection
Logging function records sensor readings for system
optimization and troubleshooting
Describes lockouts in plain English and suggests
solutions while storing last 8 errors
Standard Equipment
Factory fitted remote Wifi monitoring
Stainless steel premix burner
Direct spark ignition with variable speed blower
Full modulation with turndown ratio of 8:1
Hydraulic Separator with dirt and air separation
Automatic air vent
ASME 30 PSI pressure relief valve
Temperature and Pressure gauge
Outdoor temperature sensor
Automatic low water cutoff feature with early warning
High temperature manual reset limit safety control
Terminal block for circulator output
Low voltage terminal strip with removable jumpers
for manual or automatic reset limits
Swing up control for easy access and servicing
Polypropylene condensate pan and internal flue pipe
3 in 1 Universal vent adapter directly accepts
PVC/CPVC, Polypropylene, Stainless steel connections
with test ports
Additional external 110V socket
Project / Location: ___________________________________________ Date:
Consulting Engineer / Architect: __________________________________________________
Mechanical Contractor: _________________________________________________________