Prestige Solo 155 Condensing Gas Boiler 123

Prestige Solo Features
Light weight construction for wall mounting
Approved for zero clearance to combustibles
3” PVC, CPVC, PP, or AL29-4C venting up to 100
equivalent feet
Limited 5 year warranty on parts, except igniter
Limited 10 year warranty on heat exchanger
Approvals
95% AFUE Efficiency
ENERGY STAR Qualified
ANSI Z21.13 and CSA 4.9 Boiler Standards
Compliance
ASME Boiler Certification – ASME “H” Stamp
Low NOx operation exceeding SCAQMD 2012 regu-
lations
Stainless Steel Fire Tube Heat Exchanger
439 Stainless Steel heat exchanger construction for
corrosion resistance
Low pressure drop minimizes circulator size
High water content provides stable temperature
control
Self cleaning flue ways reduce maintenance
Suitable for use with propylene glycol up to 50%
concentration
ACVMax Control System
Graphical display with 6 navigation buttons
EZ Setup allows quick and easy boiler settings adjust-
ment
Presets allow quick configuration of 4 circulator out-
puts
Each circulator output is fully configurable for cus-
tom applications
Outdoor temperature reset to maximize efficiency
Accepts two space heating call inputs with indepen-
dent outdoor reset curves
Simultaneously heat dual temperature heating sys-
tems with built-in mixing valve control
Domestic hot water priority with optional time-out
Integrated cascade control for up to 6 Prestige boil-
ers
0-10 VDC Modulation input
Modbus building management system (BMS) inter-
face, LonWorkand BACnet® interface optional
Adjustable warm weather shutdown
Adjustable boiler freeze protection
Logging function records sensor readings for sys-
tem optimization and troubleshooting
Describes lockouts in plain english and suggests
solutions while storing last 8 errors
Standard Equipment
Stainless steel premix burner
Direct spark ignition with variable speed blower
Full modulation with turndown ratio of 5.5:1
Automatic air vent
ASME 30 PSI pressure relief valve
Integrated pressure and temperature gauge
Outdoor temperature sensor
Automatic low water cutoff feature with early warn-
ing
High temperature manual reset limit safety control
Terminal block for circulator output
Low voltage terminal strip with removable jumpers
for manual or automatic reset limits
Swing out control for easy access and servicing
Alarm and flame status contacts
Polypropylene condensate pan and internal flue
pipe
Polypropylene vent/air connections with test ports
Engineering Submittal
Prestige Solo 155
1
2016-9 Prestige ACVMax Solo 155 SubmittalDate: 12/11/2017
Project / Location:_________________________________________________________________ Date: _______________
Consulting Engineer / Architect: _________________________________________________________________________
Mechanical Contractor: _________________________________________________________________________________

Summary of content (2 pages)