Prestige Venting Supplement

34
CHAPTER 4
CHAPTER 4 - INSTALLATION REQUIREMENTS
4.4. Carbon Monoxide Detector Installation
ACV-Triangle Tube requires the installation of a mini-
mum of two (2) hard wired carbon monoxide detectors
with an alarm and battery back-up in the mechanical
room where the Prestige is located and another in-
stalled in the living area outside the bedroom(s) for all
installations.
Each carbon monoxide detector shall comply with
NFPA 720 and be ANSI/UL 2034 listed and IAS certied.
Consult the local authority having jurisdiction for any
additional carbon monoxide detector requirements in
your area. See Chapter 6 on page 37 for additional
carbon monoxide detector requirements in Massachu-
setts.
A byproduct of any gas fired appliance is
carbon monoxide. Failure to install carbon
monoxide detectors with alarms can result in
serious injury, or death.
WARNING