prestige User s Information Manual WARNING To maintain the safety & longevity of your appliance read and follow the maintenance schedule information throughout this manual. If the information in this manual is not followed exactly, a fire or explosion may WARNING result causing property damage, personal injury or loss of life. • • FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
Table of Contents Product & Safety Information Homeowner .........................................................................................................1 Technician .........................................................................................................2 Service and Maintenance...........................................................................................2 PRESTIGE Operation..............................................................................................
Table of Contents 5.9 Lockout Screen .....................................................................................................19 5.10 Manual Reset Hard Lockouts ...............................................................................20 5.11 Automatic Reset Soft Lockouts ............................................................................21 Section VI - Replacement Parts Solo 80/110 Jacket Components................................................................................
Product & Safety Information PRODUCT & SAFETY INFORMATION Homeowner The following terms are used throughout this manual to bring attention to the presence of potential hazards or to important information concerning the product. WARNING The PRESTIGE installation manual is for use only by a qualified heating installer / service technician. Refer to this User’s Information Manual for your reference. Failure to comply could result in severe personal injury, death or substantial property damage.
Product & Safety Information Technician Boiler & System Water When calling or writting about the PRESTIGE, please have the boiler model and serial number available. • • NOTICE STOP! READ BEFORE SERVICING • WARNING Failure to adhere to the guidelines on this page can result in severe personal injury, death or substantial property damage. • Service and Maintenance • To avoid electric shock, disconnect electrical supply before performing service or maintenance.
Product & Safety Information (Page left intentionally blank) 3
1.0 Combustion Air - Prevention of Contamination SECTION I - COMBUSTION AIR PREVENTION OF CONTAMINATION 1.1 - - WARNING If the PRESTIGE combustion air inlet is located in any area likely to cause or contain contamination, or if products, which would contaminate the air cannot be removed, the combustion air must be re-piped and terminated to another location.
2.0 Maintenance Schedule SECTION II - MAINTENANCE SCHEDULE 2.2 At least on an annual basis the following maintenance should be performed by a qualified service technician: - 2.1 2.2.1 Periodic Service Technician - 2.1.1 General - Inspect the interior of the boiler jacket area; clean and vacuum if necessary. - Check boiler fluid pH on systems. - - - - - - Check boiler water pressure, piping and expansion tank. - Check combustion air inlet piping. Check the pressure relief valve.
3.0 Maintenance Procedures SECTION III - MAINTENANCE PROCEDURES 1. Combustible / flammable materials - Do not store combustible materials, gasoline or other flammable vapors or liquids near the unit. Remove immediately if found. WARNING 2. Air contaminates - Products containing chlorine or fluorine, if allowed to contaminate the combustion air, will cause acidic condensate within the unit. This will cause significant damage to the unit.
3.0 3.2 Maintenance Procedures Monthly Maintenance flue gas is leaking from the condensate drain tubing by holding your fingers near the opening. 3.2.1 Check Vent Piping 3. If you notice flue gas leaking this indicates a dry condensate drain assembly. Fill the condensate drain assembly with water. Contact a qualified service technician to inspect the unit and condensate line and refill the condensate drain assembly if problem persists regularly. 1.
3.0 Maintenance Procedures 3. Have the air vent replaced by a qualified service technician if it does not operate correctly. A B WARNING To avoid water damage or scalding due to valve operation, a discharge line must be connected to the relief valve outlet and directed to a safe place of disposal. This discharge line must be installed by a qualified service technician or heating / plumbing installer in accordance with the PRESTIGE installation manual.
4.0 Operating Instructions SECTION IV - OPERATING INSTRUCTIONS A. B. WARNING FOR YOUR SAFETY READ BEFORE LIGHTING If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. This appliance does not have a pilot. It is equipped with an ignition device which automatically lights the burner. DO NOT try to light the burner by hand. BEFORE OPERATING, smell all around the appliance area for gas.
5.0 ACVMax Operation 5.1 ACVMax Navigation SECTION V - ACVMAx OPERATION The ACVMax Boiler Management System is designed to be flexible yet easy to use. ACVMax monitors and controls the Prestige to provide heat as efficiently as possible. All ACVMax features are easy to use through a graphical display where information is presented either graphically or in plain English, so code charts are not required.
5.0 5.
5.0 5.3 ACVMax Operation Home Screen The Home Screen presents status information in a very user friendly way so that the current state of the boiler can be quickly accessed. The Prestige is represented in the center of the Home Screen. Basic operating information such as supply and return temperatures are displayed as well as current burner status. A flame symbol is displayed when the unit is fired. The flame size changes to indicate the current firing rate.
5.0 5.4 ACVMax Operation Status Line Messages Status Line Message Standby CH Demand DHW Demand CH / DHW Demand DHW Priority Priority Timeout External Demand Slave Operation Manual Operation CH Burner Delay DHW Burner Delay CH Setpoint Reached DHW Setpoint Reached Description Indicates that the Prestige is ready to respond when a demand is received. A central heating call has been received. A domestic hot water call has been received.
5.0 5.4 ACVMax Operation Main Menu The Main Menu can be entered from the Home Screen by pressing the OK button. The menu system utilizes icons to represent each selection. The currently selected menu is displayed as a reversed image with a text description shown at the top of the display. Menus can be entered by highlighting the desired icon and pressing the OK button.
5.0 ACVMax Operation 5.5 CH/DHW Operation Menu The CH / DHW Operation Menu can be entered from the Main Menu by selecting the CH / DHW Operation icon and pressing the OK button. The CH / DHW Operation Menu provides a simple way to disable either the central heating or domestic hot water functions of the Prestige.
5.0 5.6 ACVMax Operation Boiler Information Boiler Information can be viewed by selecting the Boiler Information icon and pressing the OK button. Boiler Information provides real time operating information of the Prestige. Boiler Information b bbb f bbb b bb f ed cebd cba de f b b ed cba a abcc de f ab d e abc b bbb f ed bbb b bb f ed cb cba de f a abc de f bb d cba gb f abc d abc Press OK Button Currently selected menu Boiler Information Boiler Information displays six boiler readings at a time.
5.0 5.7 ACVMax Operation Information Items Information Item Boiler Status Heating Call DHW Call Boiler Firing Rate Ionization Current Boiler Setpoint Supply Temp. Return Temp. Boiler Flue Temp. Outdoor Temp. DHW Storage Temp. External Modulation Signal Pressure CH Ignitions CH Runtime DHW Ignitions DHW Runtime Mix Zone Temperature Description Displays the current operating state of the Prestige. This is the same as the status line on the home screen. Displays if a central heating call is present.
5.0 5.8 ACVMax Operation Lockout History Lockout History can be viewed by selecting the Lockout History icon and pressing the OK button. The Lockout History Screen lists the last eight lockouts along with how long ago they occurred.
5.0 ACVMax Operation 5.9 Lockout Screen The Lockout Screen replaces the Home Screen if a lockout occurs. The screen backlight will also illuminate constantly while the Prestige is locked out. Pressing any arrow button will return to the Home Screen so that additional troubleshooting can be performed. See pages 20 and 21 for a list of lockouts and descriptions.
5.0 ACVMax Operation 5.
5.0 ACVMax Operation 5.
6.0 Replacement Parts SECTION VI - REPLACEMENT PARTS WARNING Replacement parts must be purchased through a local ACV-Triangle Tube distributor. When ordering part please provide the model number and description and/or part number of replacement part. Use only genuine ACV-Triangle Tube replacement parts to ensure warranty coverage and to avoid damage to appliance and improper operation of appliance. Contact ACV-Triangle Tube at 856-228-8881 or www.triangletube.com for list of distributors nearest you.
6.0 Replacement Parts 2 4 5 3 1 Fig.
6.0 Replacement Parts 2 4 5 3 1 Fig.
6.0 Replacement Parts 6 4 5 3 2 1 Fig.
6.
6.0 Replacement Parts 2 2 5 9 1 3 6 8 4 10 7 Fig.
6.0 Replacement Parts 2 2 9 4 1 5 3 4 8 6 10 7 Fig.
6.0 Replacement Parts 2 2 3 4 9 1 5 6 4 10 8 7 Fig.
6.
6.0 Replacement Parts 9 5 4 6 2 1 3 8 Fig.
6.0 Replacement Parts 5 4 9 3 6 2 7 1 8 Fig.
6.0 Replacement Parts 5 8 4 3 6 2 1 7 Fig.
6.0 Replacement Parts 5 6 4 2 1 3 Fig.
7.
7.
Additional quality water heating equipment available from ACV- Triangle Tube Brazed Plate Heat Exchangers - For domestic water, snow melting, radiant floor, refrigeration - Plates made of stainless steel, with a 99.