Water Heater User Manual
Page 11 
Shellsol D70-Exxol D80-Sepisol KD70  190-257  - 
Shellsol A Solvesso 100 Sepisol A  162-180  - 
Shellsol AB-Solvesso 150  182-215  - 
Shellsol H-Varsol 60-Sepisol H  180-210  - 
Toluene Toulol   111   535 
Turpentine Gum Spirits   152-270   250 
Xylol/Xylene 140 525 
IMPORTANT INFORMATION: Never open the recycler prior to the suggested cool of time of 50° C. 
Always be certain that the cover gasket does not show signs of wear or have any debris attached to it. The 
green "on" light should be indicated prior to starting each cycle. 
WARNING: Never change the thermal oil before allowing the machine to cool for at least 48 hours. 
Nonflammable Solvents 
 Boiling Working 
Name Point (°C) Temp.(°C) 
Chloroform-Trichloromethane 661 90 
Methilene Chloride-DiChlormethane  40  70 
Freon 113-Frigen 113  46  80 
Carbon Tetrachloride-Tetrachloromethane  78  110 
1.1.2.2 Tetrachloroethane Acetylene Tetrachloride  147  160 
Tetrachloroethylene-Pestabil-Vors Perchloroethylene-Per  121  150 
Trichloroethane-1.1.1.3*1- Chlorothene-Genklene-Solvetane 
Baltane-Mecloran 74 110 
Tricholoethylene-Tri Vorclin-Althene-Triklone  87  120 
Warnings: 
1. When treating nonflammable solvents do not set the working thermostat at a temperature higher than that 
shown above. Higher temperatures may produce hydrochloric acid, acidify the solvent and consequently 
damage the recycler. 
2. Any solvent containing more than 35% water will not recycle successfully. 
MAINTENANCE 
Daily - A) Clean the distillation vessel …..remainder of 8.1 from Omega Manual 
 B) it is best to remove paraffin build-up when the unit is warm  
Weekly -  A) Using a soft cloth and mild solvent clean up the exterior of the 
 apparatus. 
C)  Check the thermal oil level when the unit is cold, the level should be at 
 the lower indicator. 