Datasheet

138
TYPE
Part No. (EU plug)
Part No. (UK plug)
TMS 17 Amp
301501
TMS 9 Amp
300365
TMS 55 Amp
300315
300335
Number of inputs 16 SAT, 1 TER
+ Power link
8 SAT, 1 TER 4 SAT, 1 TER
Number of outputs 16 SAT, 1 TER
+ Power link
8 SAT, 1 TER 4 SAT, 1 TER
Connectors F-con female female female
Frequency range SAT MHz 950-2150 950-2150 950-2150
Frequency range TER MHz 5-862 47-862 47-862
Return path - switchable MHz 5-30 or 5-65
Return path TER MHz 5-65 (passive)
Gain SAT 950 - 2150 MHz dB 18....24
(± 2)
14
(± 2)
20...25
(± 2)
Gain TER forward dB 17 17 (± 2) 17 (± 2)
Noise figur SAT dB < 8
Noise figur TER dB < 7
Adjustable attenuator SAT dB 0...10 0...20 0...15
Adjustable attenuator TER dB 0...10 0...20 0...17
Equalizer SAT dB 0 or 6 (switchable) 5 (fixed) 5 (fixed)
Equalizer TER dB 0...15 (adjustable) 2...15 (adjustable) 7...12 (adjustable)
Isolation SAT to SAT dB 30
Isolation TER to SAT dB 22
Max. output level SAT (IMD
3
- 35 dB)
dBµV 110 110 110
Max. output level TER (IMD
3
- 60 dB)
dBµV 105 105 105
Return loss dB 10 10 10
Impedance input/output Ohm 75 75 75
Supply voltage VDC 18 (via power link) 18 (via DC plug or trunk)
Power supply External
power adaptor
External
power adaptor
External
power adaptor
Colourcoding of IF and TER inputs Yes Yes Yes
Temperature range
o
C 0...+55 0...+55 0...+55
Dimensions (H x D x W) mm 152 x 51 x 355 152 x 51 x 253 105 x 43 x 196
Technical data
IF amplifiers. External power supply
Triax TMS 17 - 9 - 5 IF-amplifiers
Boost your signal to get more mileage.
Using a TMS line amplifier you can compensate for the cable loss in your
distribution system.
TMS 9 AMP cascadable amplifier
TMS 55 AMP cascadable amplifier
TMS 17 AMP cascadable amplifier