Technical data on
IFE series
Type
Part No.
IFE 20
323022
IFE 30
323025
IFE 12 QM
323028
IFE 16 Q
323031
Frequency range
Basic unit without RP modules
selected: VHF I “on”, RP “off”
selected: VHF I “off”, RP “on”
MHz
MHz
MHz
MHz
40-862
(1000 MHz)
40-862
(1000 MHz)
5-65/85-862 40-862
(1000 MHz)
Gain forward
Gain @ 862 MHz out 1
Gain @ 862 MHz out 2-3-4
Attenuator at input
dB
dB
dB
21
0-20
29
0-20
12
10.5
0-20
16
17
0-20
Gain return path
Gain @ 60 MHz
Attenuator elements at input
Attenuator elements at output
dB
dB
dB
-1.0
Amplitude response forward
40-862 MHz (VHF I: on)
Fix slope
Line equalizer at input
Line equalizer (2-3 dB steps)
Slope interstage
dB
dB
dB
dB
dB
1.5
+ 1
1.5
+ 1
1.5
+ 1
1.5
+ 1
Amplitude response return path 5-60 MHz
Equalizer element interstage
dB
dB
1.0
Random noise
Noise figure
Forward (VHF I „on“)
dB
dB
4.5 4.5 6.0 4.5
Return loss @ 40 MHz, -1.5 dB/octave dB > 14 > 14 > 14 > 14
Output level forward
IMR2/ IMR3 60 dB
CSO/CTB 60 dB, 42 ch. flat
dBµV
dBµV
100/113
95/98
105/113
100/100
90/103
86/89
92/103
90/90
Output level return path
IMR2/ IMR3 60 dB dBµV
RF connectors (75 Ohm)
Input
Output
Test point input: bi-directional
Test point output: directional
dB
dB
F-female
F-female
F-female
F-female
F-female
F-female
F-female
F-female
Operating conditions
Max. RF level (EMC) dBµV 105 105 105 105
Supply voltage V 230 / ±10% 230 / ±10% 230 / ±10% 230 / ±10%
Power consumption W 3 5 3 5
Operating temperature °C -25...+55 -25...+55 -25...+55 -25...+55
Protection class II II II II
Degree of protection IP 20 20 20 20
Dimensions W x H x D mm 150 x 80 x 50 150 x 80 x 50 150 x 80 x 50 150 x 80 x 50
Weight kg 0.65 0.65 0.65 0.65
Packing unit 1 pcs. carton box 1 pcs. carton box 1 pcs. carton box 1 pcs. carton box
Reference standards
Product standards/safety/EMC
RoHS 2002/95/EG compliant
EN 50083-3 - Class 2 / EN 50083-1; EN 60065 / EN 50083-2
Yes