Datasheet

188
Technical data TLT series of 5-1000 MHz outdoor 2-taps
Outdoor trunk taps with frequency ranges from 5 to 1000 MHz
All ports impedance: 75 Ohm
In-out current passing: 10 A, 60 VAC
The 100 dB RFI integrity is maintained by the use of tongue and groove design
and with a stainless steel mesh RFI gasket
Continual power through between input and output
Aluminum alloy housing is finished with a baked acrylic paint to protect from elements
Neoprene sealed and nickel-plated brass for all 5/8” port entry and taps “F-(f)” port
Provides uninterrupted power and RF service when the faceplate is removed
Triax taps - TLT series [outdoor]
TYPE
Part No.
TLT 204
80261
TLT 208
80243
TLT 211
80228
TLT 214
80234
TLT 217
80229
TLT 220
80230
Frequency range MHz 5 - 1000 5 - 1000 5 - 1000 5 - 1000 5 - 1000 5 - 1000
Inputs pcs 1 1 1 1 1 1
Outputs pcs
2 2 2 2 2 2
Insertion loss
5 - 40 MHz
40 - 470 MHz
470 - 750 MHz
750 - 862 MHz
dB
dB
dB
dB
< 3.2
< 4.0
< 5.0
< 5.0
< 2.4
< 2.5
< 3.5
< 4.0
< 1.4
< 1.8
< 2.3
< 3.0
< 1.2
< 1.6
< 2.1
< 2.4
< 0.8
< 1.3
< 1.8
< 2.2
Tap loss - output
5 - 40 MHz
40 - 470 MHz
470 - 750 MHz
750 - 862 MHz
dB
dB
dB
dB
4.0 (± 1.0)
4.0 (± 1.0)
4.0 (± 1.0)
4.0 (± 1.0)
8.0 (± 1.0)
8.0 (± 1.2)
8.0 (± 1.5)
8.0 (± 1.5)
11.0 (± 1.0)
11.0 (± 1.0)
11.0 (± 1.5)
11.0 (± 1.5)
14.0 (± 1.0)
14.0 (± 1.0)
14.0 (± 1.5)
14.0 (± 1.5)
17.0 (± 1.0)
17.0 (± 1.0)
17.0 (± 1.5)
17.0 (± 1.5)
20.0 (± 1.0)
20.0 (± 1.0)
20.0 (± 1.5)
20.0 (± 1.5)
Isolation - out/tap
5 - 40 MHz
40 - 470 MHz
470 - 750 MHz
750 - 862 MHz
dB
dB
dB
dB
> 16.0
> 24.0
> 24.0
> 23.0
> 15.0
> 22.0
> 20.0
> 18.0
> 20.0
> 24.0
> 20.0
> 18.0
> 25.0
> 24.0
> 25.0
> 25.0
> 26.0
> 28.0
> 25.0
> 23.0
> 26.0
> 28.0
> 25.0
> 23.0
Isolation - tap/tap
5 - 40 MHz
40 - 470 MHz
470 - 750 MHz
750 - 862 MHz
dB
dB
dB
dB
> 16.0
> 24.0
> 24.0
> 23.0
> 20.0
> 25.0
> 24.0
> 23.0
> 25.0
> 24.0
> 25.0
> 25.0
> 25.0
> 25.0
> 25.0
> 24.0
> 25.0
> 25.0
> 25.0
> 24.0
Return loss (out)
5 - 40 MHz
40 - 470 MHz
470 - 750 MHz
750 - 862 MHz
dB
dB
dB
dB
> 15.0
> 17.0
> 17.0
> 17.0
> 15.0
> 17.0
> 17.0
> 17.0
> 16.0
> 18.0
> 18.0
> 17.0
> 18.0
> 18.0
> 16.0
> 16.0
> 17.0
> 18.0
> 18.0
> 18.0
> 17.0
> 18.0
> 18.0
> 18.0
Shielding efficiency VHF/UHF dB 100.0 100.0 100.0 100.0 100.0 100.0
Hum modulation @ 10 A dB 66 66 66 66 66 66
Power pass connection In/out In/out In/out In/out In/out In/out
DC-throughpass A/VAC 10/60 10/60 10/60 10/60 10/60 10/60
Connectors F-connector F-connector F-connector F-connector F-connector F-connector
Certification
Impedance Ohm 75 75 75 75 75 75
Weight kg
Dimensions (h x d x w) mm
125 x 75 x 145 125 x 75 x 145 125 x 75 x 145 125 x 75 x 145 125 x 75 x 145 125 x 75 x 145
Fix-TLD bracket for wall-mounting
of splitters
Part No. 80262