Datasheet

53
OUT
DC
Rest VHF/UHFUHF CH XX
FILTER TYPE:
TRIAX
S
S
S
Triax multi channel mast combiners
TRIAX DCF range of filters/combiners
When you are using the DCF UHF series with the XX and YY channels you must
remember that there must be 2 unused channels between your specified XX and YY
UHF channels.
DCF= Double Channel Filter
Technical data on DCF multi channel mast combiners with saddle and clamp-connectors
Type
Part No.
DCF XXYY/
15A2 *)
317400
DCF XXYY/
15A3 *)
317401
DCF XXYY/
15A4 *)
317402
F XXYY/
00A1 *)
317240
F XXYY/
00A2 *)
317241
F XXYY/
00A3 *)
317242
Input 1 Band
Channel
Through loss dB
UHF
Ch. 21-69
3.0
UHF
Ch. 21-69
3.0
UHF
Ch. 21-69
3.0
UHF
Ch. XXYY
4.0
UHF
Ch. XXYY
4.0
UHF
Ch. XXYY
4.0
Input 2 Band
Channel
Through loss dB
rest
VHF/UHF
1.0
rest
VHF/UHF
1.0
rest
VHF/UHF
1.0
rest UHF
21-60
1.5
rest UHF
21-60
1.0
rest UHF
21-60
1.0
Input 3 Band
Channel
Through loss dB
BIII
5-12
1.0
VHF
2-12
1.0
VHF
2-12
1.0
Input 4 Band
Channel
Through loss dB
BI+FM
1.0
Stop band attenuation
VHF/BI
FM
BIII
UHF
SAT
dB
dB
dB
dB
dB
> 20
> 20
> 20
> 20
> 20
> 20
> 20
> 20
> 20
> 20
> 20
> 20
> 20
> 20
Numbers of in-/output 2/1 2/1 2/1 4/1 3/1 3/1
DC throughpower Ch. XXYY rest
VHF/UHF
Ch. XXYY
rest VHF/UHF
Switchable
all inputs
Ch. XXYY Ch. XXYY +
rest UHF
Connector S&C S&C S&C S&C S&C S&C
Weight kg 0.2 0.2 0.2 0.2 0.2 0.2
Dimensions Height
Depth
Width
mm
mm
mm
90
48
115
90
48
115
90
48
115
90
48
115
90
48
115
90
48
115
Remarks
*
) There must be 2 unused channels between
your specified
XX and YY UHF channels.
DCF double channel filter housing
F XXYY/00A1