Datasheet

90
Triax LNB units - the best choice
Technical data
Type
Part No.
TTW 002
Twin universal
300435
TQD 002
Quad universal
300436
TQT 002
Quattro universal
300438
TMB 002
Mono-block
300439
Colour (light grey) Ral 7035 Ral 7035 Ral 7035 Ral 7035
RF input
Input frequency range Low band
High band
GHz
GHz
10.7 ~ 11.7
11.7 ~ 12.75
10.7 ~ 11.7
11.7 ~ 12.75
10.7 ~ 11.7
11.7 ~ 12.75
10.7 ~ 11.7
11.7 ~ 12.75
Feedhorn GHz F/D = 0.615 @ 11.7 F/D = 0.615 @ 11.7 F/D = 0.615 @ 11.7 F/D = 0.615 @ 11.7
IF output
Output frequency range Low band
High band
MHz
MHz
950 ~ 1950
1100 ~ 2150
950 ~ 1950
1100 ~ 2150
950 ~ 1950
1100 ~ 2150
950 ~ 1950
1100 ~ 2150
Output connector type 75W female 75W female 75W female 75W female
Output VSWR @ room temp. 2.0:1 (max.) 2.0:1 (max.) 2.1:1 (max.) 2.0:1 (max.)
Local oscillator
Frequency Low band
High band
GHz
GHz
9.75
10.6
9.75
10.6
9.75
10.6
9.75
10.6
Frequency stability
MHz
±2.5 :1 (-40 ~+60°C) ±2.5 :1 (-40 ~+60°C) ±2.5 :1 (-40 ~+60°C) ±2.5 :1 (-40 ~+60°C)
Phase noise @ room temperature DBc/Hz
DBc/Hz
DBc/Hz
-60 @ 1 kHz (max.)
-80 @ 10 kHz (max.)
-100 @ 100 kHz (max.)
-60 @ 1 kHz (max.)
-80 @ 10 kHz (max.)
-100 @ 100 kHz (max.)
-50 @ 1 kHz (max.)
-75 @ 10 kHz (max.)
-95 @ 100 kHz (max.)
-60 @ 1 kHz (max.)
-80 @ 10 kHz (max.)
-100 @ 100 kHz (max.)
Conversion performance @ room temp.
Conversion gain (typ.)
(max.)
dB
dB
50
62
50
62
50
62
50
62
Gain variation (over operating band)
dB 5 p-p (typ.) 5 p-p (typ.) 5 p-p (typ.) 5 p-p (typ.)
Gain flatness (across 26 MHz segm)
dB ± 1.0 (typ.) ± 1.0 (typ.) ± 1.0 (typ.) ± 1.0 (typ.)
Spurious level dBm - 60 (max.) - 60 (max.) - 60 (max.) - 60 (max.)
Noise figure (Typ.)
(Max.)
dB
dB
0.3
0.6
0.3
0.6
0.3
0.6
0.3
0.6
Image rejection dB 40 (min.) 40 (min.) 40 (min.) 40 (min.)
Cross polarization isolation dB 25 typ. (20 min.) 25 typ. (20 min.) 25 typ. (20 min.) 25 typ. (20 min.)
Power requirements
DC current consumption (typ.)
mA 140 160 140 110
Operating voltage Vertical
Horizontal
VDC
VDC
10.5 ~ 14.5
15.5 ~ 21
10.5 ~ 14.5
15.5 ~ 21
10.5 ~ 21
10.5 ~ 21
10.5 ~ 14.5
15.5 ~ 21
Switching
Low band
High band
Position
Hz
KHz
0
22 ± 4
none
0
22 ± 4
none none
0
22 ± 4
DiSEqC 2.0
Operating temperature range °C -40 ~ +60 -40 ~ +60 -40 ~ +60 -40 ~ +60
Dimensions
Diameter mm 40 40 40 40
Width x Heigth x Depth mm 59 x 137 x 97 59 x 137 x 97 59 x 137 x 97 59 x 137 x 97
Max. depth incl. feedhorn mm 145 145 135 145
Weight kg 0.355 0.365 0.365 0.375
Packing size pcs. 30 30 30 30
Complete range of LNB units, adopting the latest cutting-edge RF technology
Full KU-band coverage for both analogue and digital reception
Excellent noise figure and low phase noise
High gain and excellent cross-pole isolation
High output and low power consumption
Qualified for harsh environments
Waterproof
Single packed in gift box