Programmable Multiband Amplifier TMB 100 & TMB 100S User Manual • Notice d’utilisation • Manual de usuario • Betriebsanleitung 11-2014 - V 2.
Pregrammable Amplifier TMB 100 & TMB 100S General information ........................................................................................................................... 3 Safety instructions............................................................................................................................. 3 Installing the unit ............................................................................................................................... 4 Programming the unit......
Pregrammable Amplifier TMB 100 & TMB 100S G Geenneerraall iinnffoorrm maattiioonn The processing units in the TMB100 range are used to selectively filter digital and analogue UHF channels. These units also couple and amplify VHF programmes according to the satellite band model (IF). TMB100 units have 10 UHF filters, distributed over 3 inputs with programmable bandwidth from 1 to 7 channels (8 to 56 MHz), making it suitable for most situations.
Pregrammable Amplifier TMB 100 & TMB 100S IInnssttaalllliinngg tthhee uunniitt We recommend you install the unit in a sufficiently ventilated place. Natural ventilation must be able to occur through the ventilation grids; leave a minimum space of 15 cm around the unit to ensure maximum ventilation. When installing or cabling the unit, we recommend you disconnect the mains power cable.
Pregrammable Amplifier TMB 100 & TMB 100S P Prrooggrraam mm miinngg tthhee uunniitt A 4-digit display and a keypad are all you need to programme the unit. Follow the procedure below for configuring the various parameters.
Pregrammable Amplifier TMB 100 & TMB 100S C Coonnffiigguurriinngg tthhee uunniitt On powering on, the unit is in standby mode, a light segments flashes across the display. Operating principle To access the configuration menus, press a button To summarize: To scroll through the menus, use the + / - buttons. To enter a menu, press enter.
Pregrammable Amplifier TMB 100 & TMB 100S F Fllo ow w cch haarrtt
Pregrammable Amplifier TMB 100 & TMB 100S M Meennuuss Config menu This menu allows: Configuration of filter distribution on UHF1, 2 and 3 inputs. Switch on/off the input amplifiers Selection of remote power supply (12 or 24 VDC).
Pregrammable Amplifier TMB 100 & TMB 100S Input amplifier setting. Unit in standby mode, push a button to reach the CONFIG menu. Press the enter button to select the Comb menu. Press the button to reach the AmpX menu. Press enter to activate the menu Press the buttons + or - to change the configuration of the UHF input amplifiers (on/off) Confirm by pressing enter Selection of remote power supply voltage.
Pregrammable Amplifier TMB 100 & TMB 100S Remote power supply setup.
Pregrammable Amplifier TMB 100 & TMB 100S Import and export menu Unit in standby mode, push a button to reach the CONFIG menu. Press the enter button to select the Comb menu. Press the several times to reach Import or Export menu. Press enter to activate the menu Press the buttons + or - to select the file (SE00x) Confirm by pressing enter The TMB units are equiped with RS232 interface, please used an RS232/SD adapter to store your configuration files. Important.
Pregrammable Amplifier TMB 100 & TMB 100S PIN Code Default PIN code: 2312 Unit in standby mode, push a button to reach the CONFIG menu. Press the enter button to select the Comb menu. Press the several times to reach PIN menu.
Pregrammable Amplifier TMB 100 & TMB 100S UHF filters setup. Unit in standby mode, push a button to reach the CONFIG menu. Press the button to reach the CHAN menu.
Pregrammable Amplifier TMB 100 & TMB 100S Setting the levels. There are three types of level setting: “Manual” setting of output levels (Gain menu) automatic alignment of UHF filter output levels to a value entered by the user. (Auto menu, sub-menu Level) automatic UHF gain control (Menu Auto, sub-menu AGC) Unit in standby mode, push a button to reach the CONFIG menu. Press the button several times to reach the Gain menu.
Pregrammable Amplifier TMB 100 & TMB 100S IMPORTANT! AGC: The unit memorizes the average output level. A variation of ± 1 dB triggers the function and compensates the variation within gain and attenuation limits AGC mode hides all other menus. To modify the parameters, switch the AGC mode to OFF. Auto Level: The unit memorizes the selected output level, the function try to reach the value within input, gain and attenuation limits. Note: Setting of the levels BI-II / BIII is not automatic.
Pregrammable Amplifier TMB 100 & TMB 100S TTM MB B 110000S SD Diiaaggrraam m SAT BI/FM VHF UHF1 UHF2 0/12/24V 0/13/17V UHF3 0/12/24V 0/12/24V 0/22kHz SU1 S2 S1 0-20dB 0-20dB 0-20dB 0-20dB SU2 P SU3 S4 S3 P P P P P P P P 0/9dB 0-20dB AGC OUT Note: Model TMB 100 does not have impmented the SAT path Make a note of your filter setup: UHF1 UHF2 UHF3 2 filter 8, 7 oder 5 filter 0, 1 ou 3 filter Bandwidth of the filter 47 .,. 108 MHz 174 ... 230 MHz (1 .. 7 Kanäle) 8 ..
Pregrammable Amplifier TMB 100 & TMB 100S Technical Specifications Type Part nr. Number of inputs TMB 100 360223 5 TMB 100S 324580 6 90 / 80 / 95 / - 90 / 80 / 95 / 80 32 48 55 9/5/7/0 ... 20 0 ... 20 32 48 55 40 0/9 (switchable) 9/5/7/7 0 ... 20 0 ... 20 120/120 / 117 / - 120 / 120 / 115 / 118 Units AMPLIFICATION Max. BI+FM / BIII / UHF / SAT input level BI+FM (47 .. 108 MHz) gain BIII (174 .. 230 MHz) gain UHF ("LTE on": 470 .. 790 MHz; "LTE off": 47 .. 862 MHz) gain SAT (950 ..
TRIAX A/S Bjørnkærvej 3 • DK-8783 Hornsyld Tel: +45 76 82 22 00 • Fax: +45 88 20 04 20 mail: triax@triax.dk • www.triax.com User Manual • Notice d’utilisation • Manual de usuario • Betriebsanleitung 11-2014 - V 2.