Brochure

Pregrammable Amplifier
TMB 100 & TMB 100S
IMPORTANT!
AGC: The unit memorizes the average output level. A variation of ± 1 dB triggers the
function and compensates the variation within gain and attenuation limits
AGC mode hides all other menus. To modify the parameters, switch the AGC mode to OFF
.
Auto Level: The unit memorizes the selected output level, the function try to reach the value
within input, gain and attenuation limits.
Note: Setting of the levels BI-II / BIII is not automatic.
SAT Menu
TMB 100S models have one IF amplification path. The Sat menu is used to configure the remote
power supply of the LNB (OFF / 13 /17 V
DC), to activate the 22kHz generator and the 9dB equalizer.
Unit in standby mode, push a button to reach the CONFIG menu.
Press the button several times to reach the SAT menu.
Press enter to activate the SAT menu
Press the or button to select the Supp, Gain, Eq, Pol or Band menu.
o Supp (power on or off)
o Gain
o Eq (Equalizer 0dB_off or 9dB_on)
o Pol (H or V polarization)
o Band (Lo/H Band)
Press enter to activate the selected menu
Press the buttons + or - to change the value
Confirm by pressing enter