TROUBLESHOOTING
Status
The Slowstar
®
does not work
Motor stops during use
Amount of juice is too little
Juice Container is shaking in the
middle of operation
Seems like the Duoblade
Auger is
grinding
Hearing a lot of sounds coming from
the Slowstar
®
Juice is spilling out of the Slowstar
®
After extraction, the color of the Juicing
parts and Juice Container are different
The Feeding Chute Assembly does not
disassemble easily
Check if the power cord is plugged in properly.
Check if all parts are assembled correctly.
Check if the power cord is plugged in properly.
Check if all parts are assembled correctly.
The Slowstar
®
may not work if too many juicing ingredients
are inserted at the same time.
If the Slowstar
®
stops in the middle of operation, then
turn the switch to ‘OFF’ and then turn the switch to
‘REVERSE’ to unclog the materials in the Duoblade
Auger.
Then turn the switch to “ON” to push the materials down.
(Repeat this step 3 times)
Turn the switch to “OFF” and place the Main Body in a
cool area. Let the Slowstar
®
rest for an hour to cool the
motor down and try turning the Slowstar
®
on again.
Remove all the hard seeds in the juicing ingredients
before juicing. Hard seeds may break down the Juicing
Screen and Duoblade
Auger.
• Each food produces a different amount of juice depending
on how fresh it is.
To extract more juice, refrigerate ingredients then
soak for about 10 minutes in clean water before juicing.
Check if the Pressure Plug is assembled properly.
It is completely normal if the juice container shakes a
little bit during operation.
Operating the Slowstar
®
without feeding any food may
cause the Duoblade
Auger to grind.
Turn the switch to “OFF” then check if the parts are
assembled properly.
Check if the Slowstar
®
is operating on an uneven surface.
There may be some squeaky friction noise while in use.
This is a normal sound that occurs, and user should not
worry about it.
Check if juicing materials are cut to the right sizes.
Check if pressure plug is assembled properly. It might
happen if the Pressure Plug is not assembled properly.
• Right after use, if the Slowstar
®
is not cleaned, then it is
more difficult to clean and may even result in performance
resistance.
The color of Beta-Carotene which is in carrots and spinach
might affect the color of the Slowstar
®
parts. Wash it out
with cooking oil first, and then use soap and warm water.
Disassemble Silicone Blades and wash them separately.
Grab the Feeding Chute firmly and rotate it counter-
clockwise with force.
Checklist