Grounding Checklist
When grounding a SkyPilot device, use the following checklist to confirm
that your installation is adequately protected from power surges and
lightning.
Connect a ground wire from the SkyPilot device to a ground system
on the building or tower.
Use shielded CAT5 cabling and connect the drain wire of the shield to
ground at the SkyPilot device. (Leave the other end of the drain wire
unconnected.)
Use the proper size down lead to connect a SkyPilot device on a roof
or tower to the ground system of indoor equipment.
Verify that all points of the ground system are tied together with less
than 5 ohms resistance between any two points.
Run the CAT5 cable inside the tower structure, tying the cable to the
tower leg at every 4 feet of length. For increased protection, run the
CAT5 cable through metallic conduit installed on the tower.
Bleed off any static charge by installing a streamer-delaying, static-
dissipation array above the SkyPilot device.
Install all lightning and surge protection devices in accordance with
UL 96A installation requirements for lightning protection systems and
the NFPA 780 standard for lightning protection.