User's Manual

U-Link TRx User Guide
Ref. 09-03-V1.0 p 8
Frequency Range
The frequency range is 450MHz up to 470MHz.
Input RF filters bandwidth is the central frequency adjusted in factory +/- 3MHz.
Channel Spacing
The channel spacing is 12.5 kHz.
Modulation
The transceiver is able to process GMSK BT=0.5 modulation with raw data throughput
of 9600 bits/s.
Transmitter output power
The RF output power on 50ohms load is software selectable between: 0.5W (27dBm),
2W (33dBm), and 4W (36dBm).
Receiver RF sensitivity
The digital sensitivity is typically –110 dBm at 10
5
BER.
RF Connector
The RF connector is a 50 ohms standard TNC female connector.
Antenna
The product will be used with the PROCOM ANTENNA FSP70/460-FME .
Temperature range
From -30°C to +55°C
Regulatory
Compliant with FCC CFR47 part 90