User's Manual

Table Of Contents
PDL User's Guide 31
Code Description
E01 External voltage too high
E02 External voltage too low
E03 External voltage too low for transmission
E04 Rover internal battery requires replacement
E05 Rover internal battery charge current too high
E06 Rover internal battery charge current too low
E07 Unit temperature exceeds safe limit for 35 W operation
E08 Unit temperature exceeds safe limit for 2 W operation
E09 Current consumption too high for 35 Watt operation
E10 Current consumption too high for 2 Watt operation
E11 Checksum error
E12 RAM error
E13 EEPROM error
E14 FLASH error
E16 Synthesizer not locked
E17
E18 Charger voltage not adequate to charge unit
E99 Unknown error
Table 2 - PDL Error Codes
What to do
E01-E03, E18 Check battery or power supply voltage level,
check power cables, recharge or replace battery, check charger.
E07-E10 Check antenna and antenna cables, use 19200 link
rate to reduce duty cycle, select low RF power.
E04-E06, E11-E16, E99 Contact customer service.