User Manual

11
Start Reference Check
Before starting some grade work which is very sensitive an additional Reference Check can
bestartedmanually. Press and release the MENUbuttonattheStandardDisplayandselect
ReferenceCheck.
Pressing and releasing button 4startstheReferenceCheckconsideringthecurrenttemperature
insidethehousing.Whiletherotorchecksthecorrectpositiontherotationwillbestopped.
Centering the Rotor
PressandreleasetheMENUbuttonattheStandardDisplayandselectCenteringwheretherotor
willbecentered90°perpendiculartothebottomhousing.
Pressing and releasing button 4 starts the rotor centering function while the rotor checks the
limitsofbothaxesthenitstopsatthecenterpositionandchangestheunitintomanualmode.
Setting Menu
PressandreleasetheMENUbuttonattheStandardDisplayandselectSettings.
Press and release button 4toopentheSettingMenu;selectthedesiredfunctionthenpressbutton
4toopentheselectedsubmenufunctionORstarttheselectedfunction.
PleaseseetheSettingMenudetailsattheendoftheuserguide.
Info
PressandreleasetheMENUbuttonattheStandardDisplayandselectInfo.
Buttons6/7canbeusedtotogglebetweenUL,RCandRuntime.
Press and release button 4toconrmtheselection.
TheUL/RCinformation(softwareversion,ID,etc.)ortheruntimeoftheULwillbedisplayed.
Service
PressandreleasetheMENUbuttonattheStandardDisplayandselectService.Buttons6/7 can be
used to toggle between Calibration Y and Calibration XOR Calibration Z when set up vertically.
Press and release button 4 to conrm the selection. The calibration at the selected axis starts the eld
calibration procedure.