Date: 2018.7.16
Doc No: PS-M-0434
Ver. D
Page - 17 - of 17
module output to prevent battery discharge at night.
• Product Replacement:
In the event that a module is damaged (broken glass or scratch on back sheet) and needs to be replaced
then
Observe the safety precautions listed earlier in the manual
Wear cut resistant gloves and other personal protective equipment required for the particular
installation.
Isolate the impacted array string to prevent current flow before attempting to remove the module.
Disconnect the connectors of the affected module using the related disconnect tool provided by
suppliers.
Replace the damaged module with a new module of the same type.
Check the open circuit voltage of the array string and verify that this is within 10V of the other strings to
be connected in parallel.
Turn the isolator back on.
• Troubleshooting:
If your installation does not work properly, please inform your installer immediately.
• Reporting Technical Issues or Claims:
Contact your installer
Contact Trina Solar after sales service team at http://customerservice.trinasolar.com/
Submit the Customer Feedback form at: http://www.trinasolar.com/ and one of our technical service
representatives will contact you within 5 business days. A username and password is required to send
feedback from the customer service link
For module specifications or datasheets, please download from: http://www.trinasolar.com/
WARNING: For any electrical maintenance, the PV system must first be shut down. Improper
maintenance can cause lethal electric shock and/or burns.
Edition Revision Date Revised Item Revised Content
New Edition 2016.05.05
2
nd
Edition 2017.02.20
1. Add unit of UL mechanical measuring
2. Add connector
1. Pa psf
2. Clarify detail connector.
3rd Edition
2017.05.27
Module size standardization
1.
Figure 1, add Installing hole
note
2. Figure 3, use
distance of
installing holes instead of
module size
4
th
Edition
2017.07.14 Add connector Add four types of connector
5
th
Edition
2018.07.16 Modules added Half-Cut Products (H)
9. WARNING