User manual

TMCM-1180 and PD86-1180 TMCL Firmware V4.42 Manual (Rev. 1.08 / 2012-NOV-20) 26
www.trinamic.com
Example:
Move motor to previously stored coordinate #8
Mnemonic: MVP COORD, 0, 8
Binary:
Byte Index
0
1
2
3
4
5
6
7
8
Function
Target-
address
Instruction
Number
Type
Motor/
Bank
Operand
Byte3
Operand
Byte2
Operand
Byte1
Operand
Byte0
Checksum
Value (hex)
$01
$04
$02
$00
$00
$00
$00
$08
$11
When moving to a coordinate, the coordinate has to be set properly in advance with the help of
the SCO, CCO or ACO command.