Datasheet

PD57/60-1076 TMCL
Firmware Manual Firmware Version V1.02 | Document Revision V1.00 2018-MAR-26
27 / 38
All Global Parameters of the PD57/60-1076 Module in Bank 0
Number Global Parameter Description Range [Units] Default Access
65 Serial baud rate RS485/RS232 baud rate
0 - 9600 baud
1 - 14400 baud
2 - 19200 baud
3 - 28800 baud (not supported by
TMCL-IDE)
4 - 38400 baud
5 - 57600 baud
6 - 76800 baud
7 - 115200 baud
0 . . . 7 0 RWA
66 Serial address
The module (target) address for
RS485, RS232, and virtual COM port.
1 . . . 255 1 RWA
76 Serial host
address
Host address used in the reply tele-
grams sent back via RS485/RS232.
1 . . . 255 2 RWA
132 Tick timer TMCL tick timer. 0
. . . 4294967295
0 RW
Table 10: All Global Parameters of the PD57/60-1076 Module in Bank 0
©2018 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.
Download newest version at www.trinamic.com