112 / 158
Address Registername Access
Mask Name Type
0xFFFFFFFF
h
SINGLE_PIN_IF_TARGET_VELOCITY Signed
Min Max Default Unit
-2147483648 2147483647 0
Variant 44
Mask Name Type
0xFFFFFFFF
h
SINGLE_PIN_IF_TARGET_POSITION Signed
Min Max Default Unit
-2147483648 2147483647 0
Variant 192
Mask Name Type
0x0000FFFF
h
DEBUG_VALUE_0 Signed
Min Max Default Unit
-32768 32767 0
Mask Name Type
0xFFFF0000
h
DEBUG_VALUE_1 Signed
Min Max Default Unit
-32768 32767 0
Variant 193
Mask Name Type
0x0000FFFF
h
DEBUG_VALUE_2 Signed
Min Max Default Unit
-32768 32767 0
Mask Name Type
0xFFFF0000
h
DEBUG_VALUE_3 Signed
Min Max Default Unit
-32768 32767 0
Variant 194
Mask Name Type
0x0000FFFF
h
DEBUG_VALUE_4 Signed
Min Max Default Unit
-32768 32767 0
Mask Name Type
0xFFFF0000
h
DEBUG_VALUE_5 Signed
Min Max Default Unit