3.6.3 MST (Motor Stop)
The motor is instructed to stop with a soft stop.
Internal function:
The velocity mode is selected. Then, the target speed (axis parameter #0) is set to zero.
Related commands: ROR, ROL, SAP, GAP.
Mnemonic: MST <axis>
Binary Representation
Instruction Type Motor/Bank Value
3 0 0. . . 2 0
Reply in Direct Mode
Status Value
100 - OK dont care
Example
Stop motor 0.
Mnemonic: MST 0.
Binary Form of MST 0
Field Value
Target address 01
h
Instruction number 03
h
Type 00
h
Motor/Bank 00
h
Value (Byte 3) 00
h
Value (Byte 2) 00
h
Value (Byte 1) 00
h
Value (Byte 0) 00
h
Checksum 04
h