3.6.29 CLE (Clear Error Flags)
This command clears the internal error ags. It is mainly intended for use in standalone mode.
The following error ags can be cleared by this command (determined by the <ag> parameter):
ALL: clear all error ags.
ETO: clear the timeout ag.
EAL: clear the external alarm ag.
EDV: clear the deviation ag.
EPO: clear the position error ag.
Related commands: JC, WAIT.
Mnemonic: CLE <ags>
Binary Representation
Instruction Type Motor/Bank Value
36 0 ALL all ags 0 (dont care) 0 (dont care)
1 (ETO) timeout ag
2 (EAL) alarm ag
3 (EDV) deviation ag
4 (EPO) position ag
5 (ESD) shutdown ag
Reply in Direct Mode
Status Value
100 - OK dont care
Example
Reset the timeout ag.
Mnemonic: CLE ETO