Number Axis Parameter Description Range [Units] Access
6 Maximum
current
Motor current used when motor is running. The
maximum value is 255 which means 100% of
the maximum current of the module.
The current can be adjusted in 32 steps:
0. . . 7 79. . . 87 160. . . 167 240. . . 247
8. . . 15 88. . . 95 168. . . 175 248. . . 255
16. . . 23 96. . . 103 176. . . 183
24. . . 31 104. . . 111 184. . . 191
32. . . 39 112. . . 119 192. . . 199
40. . . 47 120. . . 127 200. . . 207
48. . . 55 128. . . 135 208. . . 215
56. . . 63 136. . . 143 216. . . 223
64. . . 71 144. . . 151 224. . . 231
72. . . 79 152. . . 159 232. . . 239
The most important setting, as too high values can
cause motor damage.
0. . . 255 RW
7 Standby
current
The current used when the motor is not running.
The maximum value is 255 which means 100% of
the maximum current of the module. This value
should be as low as possible so that the motor
can cool down when it is not moving. Please see
also parameter 214.
0. . . 255 RW
8 Position
reached ag
This ag is always set when target position and
actual position are equal.
0/1 R
9 Home switch
state
The logical state of the home switch input. 0/1 R
10 Right limit
switch state
The logical state of the right limit switch input. 0/1 R
11 Left limit
switch state
The logical state of the left limit switch input. 0/1 R
12 Right limit
switch disable
Deactivates the stop function of the right limit
switch if set to 1.
0/1 RW
13 Left limit
switch disable
Deactivates the stop function of the left limit
switch if set to 1.
0/1 RW
14 Swap limit
switches
Swap the left and right limit switches when set
to 1.
0/1 RW
15
Acceleration A1
First acceleration between VSTART and V1 (in
position mode only).
0. . . 7629278
[pps
2
]
RW