User Manual

TMCM-3351 CANopen® Firmware Manual Firmware Version V3.22 | Document Revision V1.01 2019-FEB-14
107 / 145
5
Index pulse
Home switch
5
Figure 18: Homing Method 5
8.1.5 Homing Method 17: Homing on negative Limit Switch
Using this method, the initial direction of movement shall be leftward if the negative limit switch is inactive
(here: low). The home position shall at the point where the negative limit switch becomes inactive.
17
Negative limit switch
17
Figure 19: Homing Method 17
8.1.6 Homing Method 18: Homing on positive Limit Switch
Using this method, the initial direction of movement shall be rightward if the positive limit switch is inactive
(here: low). The home position shall be at point the where the positive limit switch becomes inactive.
18
18
Positive limit switch
Figure 20: Homing Method 18
©2019 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.
Download newest version at www.trinamic.com