Object Description
Index Name Object Type Data Type
60C2
h
Oset Torque Vecord Interpolation time period record (0080
h
)
Table 408: Object Description (60C2
h
)
Entry Description
Sub-index Description Access PDO Mapping Value Range Default Value
0 Highest sub-index supported ro no UNSIGNED8 2
1
Interpolation time period value
rw no UNSIGNED8 1
2 Interpolation time index rw no -3. . . 3 -3
Table 409: Entry Description (60C2