Motor Velocity [pps]
Load Angle [µSteps]
2034h
2035h
2036h
2027h
(max. 90°)
Field Weakening
Normal Closed Loop
max. 180°
Figure 6: Field Weakening
Object 2027
h
: Closed-loop beta.
Object 2036
h
: Field weakening (closed-loop gamma).
Object 2034
h
: Field weakening minimum velocioty (gamma Vmin).
Object 2035
h
: Field weakening maximum velocioty (gamma Vmax).
1.5.5 Position Catch up
The TMCM-3351 includes a special feature for closed-loop positioning. Positioning parameters like velocity
and acceleration will be calculated to reach a position in a dedicated time. If the target trapezoidal ramp
cannot be maintained due to high load peaks the TMCM-3351 includes a special position catch-up mode
to ensure that the position will still be reached in time if possible.
Figure 7: Position Catch up