User Manual

TMCM-3351 CANopen® Firmware Manual Firmware Version V3.22 | Document Revision V1.01 2019-FEB-14
54 / 145
Object Description
Index Name Object Type Data Type
204E
h
Field weakening Variable UNSIGNED8
Table 125: Object Description (204E
h
)
Entry Description
Sub-index Access PDO Mapping Value Range Default Value
0 rw no 0. . . 255
Table 126: Entry Description (204E
h
)
4.2.36 Object 2089
h
: Setting Delay
This object has to be used for setting a standstill period before the current is changed down to standby
current.
Unit: 10msec
Object Description
Index Name Object Type Data Type
2089
h
Setting Delay Variable UNSIGNED16
Table 127: Object Description (2089
h
)
Entry Description
Sub-index Access PDO Mapping Value Range Default Value
0 rw no 0. . . 65535 200
Table 128: Entry Description (2089
h
)
4.2.37 Object 208C
h
: Velocity Dimension Index
With this object dierent units can be chosen:
Writing 0 selects internal units.
Writing 181 sets PPS for velocity and PPS/s for acceleration.
This can only be changed in SWITCHED_ON_DISABLED mode.
©2019 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.
Download newest version at www.trinamic.com