User Manual

TMCM-6212 CANopen
®
Firmware Manual Firmware Version V3.22 | Document Revision V1.05 2019-FEB-13
121 / 131
Object Description
Index Name Object Type Data Type
60C2
h
Oset Torque Vecord Interpolation time period record (0080
h
)
Table 352: Object Description (60C2
h
)
Entry Description
Sub-index Description Access PDO Mapping Value Range Default Value
0 Highest sub-index supported ro no UNSIGNED8 2
1
Interpolation time period value
rw no UNSIGNED8 1
2 Interpolation time index rw no -3. . . 3 -3
Table 353: Entry Description (60C2
h
)
©2019 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.