User Manual

TMCM-6212 CANopen
®
Firmware Manual Firmware Version V3.22 | Document Revision V1.05 2019-FEB-13
30 / 131
Object Description
Index Name Object Type Data Type
1400
h
1403
h
Receive PDO parameter RECORD RPDO CommPar
1400
h
RPDO 1 RECORD RPDO CommPar
1401
h
RPDO 2 RECORD RPDO CommPar
1402
h
RPDO 3 RECORD RPDO CommPar
1403
h
RPDO 4 RECORD RPDO CommPar
Table 46: Object Description (1400
h
)
Entry Description
Sub-index Description Access Value Range Default Value
00
h
Largest sub-index
supported
ro 2 2
01
h
COB-ID used by
PDO
rw UNSIGNED32 Index 1400
h
: 200
h
+ Node-ID
Index 1401
h
: 300
h
+ Node-ID
Index 1402
h
: 400
h
+ Node-ID
Index 1403
h
: 500
h
+ Node-ID
02
h
Transmission type rw UNSIGNED8 Index 1400
h
: FF
h
Index 1401
h
: FF
h
Index 1402
h
: FF
h
Index 1403
h
: FE
h
Table 47: Entry Description (1400
h
)
3.1.19 Objects 1600
h
1603
h
: Receive PDO Mapping Parameter
These objects contain the mapping parameters for the RPDOs the device is able to receive. The sub-index
00
h
contains the number of valid entries within the mapping record. This number of entries is also the
number of the application variables which shall be received with the corresponding RPDO. The sub-indices
from 01
h
to the number of entries contain the information about the mapped application variables. These
entries describe the PDO contents by their index, sub-index and length.
The RPDOs dened by objects 1600
h
1603
h
(RPDO 1. . . 3) are normally used for motor #0. For the other
motors, the following RPDOs are used:
RPDO 65. . . 68 (objects 1640
h
1643
h
) for motor #1.
RPDO 129. . . 132 (objects 1680
h
1683
h
) for motor #2.
RPDO 193. . . 196 (objects 16C0
h
16C3
h
) for motor #3.
RPDO 257. . . 260 (objects 1700
h
1703
h
) for motor #4.
RPDO 321. . . 324 (objects 1740
h
1743
h
) for motor #5.
©2019 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.
Download newest version at www.trinamic.com