User Manual
TMCM-6212 CANopen
®
Firmware Manual • Firmware Version V3.22 | Document Revision V1.05 • 2019-FEB-13
44 / 131
4.2.13 Object 2012
h
: Profile V1
This object contains the velocity used for the first segment of a positioning ramp.
Object Description
Index Name Object Type Data Type
2012
h
Profile V1 Variable UNSIGNED32
Table 81: Object Description (2012
h
)
Entry Description
Sub-index Access PDO Mapping Value Range Default Value
0 rw no 0. . . 16777215 0
Table 82: Entry Description (2012
h
)
4.2.14 Object 2013
h
: Profile D1
This object contains the deceleration value used for decelerating from the maximum positioning velocity
to the velocity V1 (object 2012
h
, see section 4.2.13).
Object Description
Index Name Object Type Data Type
2013
h
Profile D1 Variable UNSIGNED32
Table 83: Object Description (2013
h
)
Entry Description
Sub-index Access PDO Mapping Value Range Default Value
0 rw no 0. . . 16777215 0
Table 84: Entry Description (2013
h
)
4.2.15 Object 2015
h
: Ramp Wait Time
This object defines the waiting time after ramping down to zero velocity before the next movement or
direction inversion can start. Time range is 0 to 2 seconds. This setting avoids excess acceleration e.g. from
positive stop velocity to negative start velocity.
©2019 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.