Multicast
】:
Broadcast
broadcast only conduct Mode 1, the entire network conduct broadcast mode
experiment, other modes test by themselves
Data function transmission needs to reflect its own characteristics in the case of multi-node network, the users can test
by themselves
8. User instruction set
In order to facilitate user use, D2106-THGN01 ZigBee module uses two instruction formats, namely AT instruction
format and HEX instruction format. The format mode is controlled by default P1_6.
When P1_6 = 0, the module enters HEX instruction mode. In this mode, input +++, enter the temporary AT
instruction mode. AT command can be used to configure, input AT + EXIT exit temporary AT command.
When P1_6 = 1, the module enters AT instruction mode. Line break endings cannot be used in AT instructions.
Remarks
1 Serial data format error message
HEX instruction mode F7 FF
AT instruction mode +ERROR<CR><LF>
2 Coordinator device network establishment will prompt information:
HEX instruction mode FF FF
AT instruction mode Builded network<CR><LF>
3 Devices joining the network will prompt information
HEX instruction mode FF AA
AT instruction mode Joined network<CR><LF>