User's Manual

Page 39
E Series Ethernet Radio – User Manual
Version 08-10
Communications Ports
The Data Port and System Port of each Base Station connect
directly to the Hot Standby Controller units corresponding ports
with the cables provided. Ensure all clamping screws on the Data
Port cables are rmly secured and the System Port cables are
clipped in correctly. See gure below for further details.
Note: Only the front or rear User System Port can be used at any
one time on the Hot Standby Controller.
Power Supply and Protection
The EH45e has facilities for dual power supplies to provide for a
redundant system. A separate power supply should be used for
each of the Base Station units. The Hot Standby Controller unit has
connections for dual power supplies and it is recommended that
the power supplies from each of the Base Stations also be used to
power the Hot Standby Controller unit. See Figure below for further
details. See ER45e Quick Start Guide Section for detailed wiring
information.
The Hot Standby Controller units B Data Port connects directly to
your application device and the System Port connects directly to
your local PC. See EH45e Quick Start Guide Section for further
details.
Part E – Getting Started - EH450
Note: HSC RF Connectors not used on ETSI version