Power Supply Requirements
The M Series radio modem is designed and calibrated to operate from
a filtered 13.8Vdc regulated supply, but will operate from a 10-16Vdc
range. See the User Manual for more details on power supply
requirements.
Caution: There is NO internal replaceable fuse and therefore
an external fuse MUST be fitted as shown in diagram below
(MR450: 3 amp slo-blow fuse, EB450: 5 amp fast-blow fuse,
EH450 Controller 1 amp slo-blow fuse).
The radio is designed to self protect, and will blow the external fuse if
the voltage exceeds 16Vdc, or if reverse polarity is applied.
The radio modem can also be damaged if there is any potential
difference between the chassis-ground, RS232 signal ground, power (-
) input, or antenna coaxial shield. Before connecting any wiring,
ensure all components are earthed to a common ground point (please
pay particular attention to 24V PLC power systems where converters
are used).
Connect the antenna and RS 232 plugs BEFORE applying power to
the unit.
Lastly, before inserting the power plug, please
re-check that the polarity and voltage on the
power plug is correct using a multimeter.
Failure to use an external fuse will result in
damage to the radio which will void the warranty.
TVIEW+ Management Suite - Radio Configuration
This TVIEW+ Management Suite provides a facility for local radio
configuration and diagnostics.
Example: Configuration session –
1 Attach the TVIEW+MSeries cable between the radio Data Port
A and the PC serial port. Ensure the Configuration/Diagnostics
plug is connected to the PC serial port and NOT the User Data
plug.
2 Launch TVIEW+ & Select “Programmer”
3 Select “Read” the radio
4 Change the configuration as required
5 Select “Write” the parameters back to the radio
Refer to to the User Manual for detailed operation of advanced
features.
Part E – Getting Started- MR450