Part G – Maintenance
Routine Maintenance
Considerations
The M Series hardware itself does not require routine maintenance.
However all radio products contain crystal frequency references, and
the stability of these crystals change with time. The effect of this is that
the product will slowly drift off frequency, and eventually it will require
re-calibration. M Series radios are designed with high quality, low drift
specification references, to ensure a long maintenance free lifespan.
The length of this lifespan will depend on the severity of temperature
extremes in the operating environment, but is normally 3–5 years.
Extended frequency drift can be detected using TVIEW+ Diagnostics
“Freq error” parameter.
Re-calibration is achieved by replacing the radio in the field with a
spare, and returning the radio to a service centre for re-calibration and
specification testing at moderate cost.
Routine maintenance should be performed on external equipment
subject to greater environmental stresses including antennas, RF
feeder cables, backup batteries and cooling fans (if required). This
maintenance should include testing of site commissioning figures such
as received signal strength, VSWR, P/S voltage etc.