Serial data transport via PPP
Connect your PC’s Ethernet port to ETH1 or ETH2 of the radio being configured and using a web browser, browse to the
radio’s configuration page by entering the IP address the unit into the browser’s URL bar. Once the configuration has been
activated, repeat the process for the remaining radio.
To access the parameters below, browse to the “Setup” tab and select the “COM1” option under “Configuration”.
The example uses the following IP addresses for external PPP Clients: ‘Host Application - 192.168.2.20’ ‘External Device
(RTU) - 192.168.2.30’
Host Application
IP: 192.168.2.20
External Device
IP: 192.168.2.30
Remote - 192.168.2.17
COM1:
Mode: Serial Device Server
(b) Baud Rate: match the Baud Rate of the
external serial device you are connecting to
the Q data radios Serial Port.
(c) Protocol: PPP
(d) Client IP Address: 192.168.2.30
Entry Point - 192.168.2.16
COM1:
Mode: Serial Device Server
Baud Rate: match the Baud Rate of the
external serial device you are connecting
to the Q data radios Serial Port.
Protocol: PPP
Client IP Address: 192.168.2.20
Part G – Quick Start Guide