User's Manual

150 Document Number: 0100SM1401 Issue: 12-16
Part H – Advanced
Operational Alarm Detection Notification
Notification Name notificationOperationalAlarm
Notification OID .1.3.6.1.4.1.33302.30.10.1
Operational Alarm Detection Notification Objects
Name OID Position Specific
Code
Description
operationalAlarm .1.3.6.1.4.1.33302.30.5.1.0 0 1 Operational alarm state
PLL Lock Alarm Detection Notification
Notification Name notificationPllLock
Notification OID .1.3.6.1.4.1.33302.30.10.2
PLL Lock Notification Objects
Name OID Position Specific
Code
Description
rxPllLocked .1.3.6.1.4.1.33302.30.5.2.0 0 2 Receiver PLL lock alarm state
txPllLocked .1.3.6.1.4.1.33302.30.5.17.0 1 2 Transmit PLL lock alarm state
VSWR Alarm Detection Notification
Notification Name notificationVswr
Notification OID .1.3.6.1.4.1.33302.30.10.4
VSWR Notification Objects
Name OID Position Specific
Code
Description
radioVswrAlarmState .1.3.6.1.4.1.33302.30.5.10.1.2.1 0 4 VSWR alarm state
radioVswr .1.3.6.1.4.1.33302.30.2.7.1.2.1 1 4 VSWR value
Temperature Alarm Detection Notification
Notification Name notificationTemperature
Notification OID .1.3.6.1.4.1.33302.30.10.5
Temperature Notification Objects
Name OID Position Specific
Code
Description
temperatureAlarmState .1.3.6.1.4.1.33302.30.5.12.0 0 5 Temperature alarm state
temperatureC .1.3.6.1.4.1.33302.30.1.13.1.3.1 1 5 Temperature value (Celsius)
temperatureF .1.3.6.1.4.1.33302.30.1.13.1.4.1 2 5 Temperature value (Fahrenheit)
Supply Voltage Alarm Detection Notification
Notification Name notificationSupplyVoltage
Notification OID .1.3.6.1.4.1.33302.30.10.6
Supply Voltage Notification Objects
Name OID Position Specific
Code
Description
externalSupplyVoltageAlarmState .1.3.6.1.4.1.33302.30.5.11.0 0 6 Supply voltage alarm state
supplyVoltage .1.3.6.1.4.1.33302.30.1.12.0 1 6 Supply voltage value