Global Alarm Detection
Name globallAlarm
Alarm states Normal (1), User alarm (2) and Critical alarm (3)
Global alarm detection can change alarm state, based on the highest active alarm state (1 Normal state, 2 User alarm state, 3
Critical alarm state) of all the other SNMP alarm detection objects within the alarm group (with the exception of operational alarm).
SNMP - User Alarm Object Specifications
External Supply Voltage Alarm Detection
Name externalSupplyVoltageAlarmState
Alarm states Normal (1), User alarm (2) and Critical alarm (3)
User alarm limits Configurable upper and lower limit, 10000 to 30000 (mVDC)
Critical alarm limits Lower hardware limit: 9500 (mVDC), Upper hardware limit: 30500 (mVDC)
Hysteresis +/- 500 (mVDC)
VSWR Alarm Detection
Name radioVswrAlarmState
Alarm states Normal (1), User alarm (2) and Critical alarm (3)
User alarm limits Optional limit, 1.5:1, 2:1 or 3:1
Critical alarm limits hardware limit: >10:1.
Hysteresis None
Radio Temperature Alarm Detection
Name temperatureAlarmState
Alarm states Normal (1), User alarm (2) and Critical alarm (3)
User alarm limits Configurable upper and lower limit, -40 to +70 (Deg C)
Critical alarm limits Upper hardware limit: +75 (Deg C). (No lower limit)
Hysteresis
+/- 5 (Deg C)
Radio RSSI Alarm Detection
Name radioRssiAlarmState
Alarm states Normal (1) and User alarm (2)
User alarm limits Configurable upper and lower limit, -140 to 0 (dBm)
Hysteresis
+/- 10 (dBm)
Radio Transmit Power Alarm Detection
Name radioTxPowerAlarmState
Alarm states Normal (1) and User alarm (2)
User alarm limits Configurable upper and lower limit, 0 to +40 (dBm)
Hysteresis +/- 10 (dBm)