User's Manual

System failure indication table
OPERATION Location Control indication
1 No communication Communications
light flashing or off.
1. Check the battery voltage in the flood detector.
2. Consider narrowing the transmission distance.
3. Considering adding a relay (repeater.)
2 Valve fault All the indicator,
apart for the voltage,
flash twice or three
times every 15
seconds
1. Make sure there are no obstructions in the valve's opening and
closing path.
2. Open and close the valve using the controller buttons
3. Extract and replace the batteries in the valve and check the fault
status.
4. Replace the valve.
3 Low water battery Valve battery
indicator is
continuously on.
Replace the valve battery
4 The circuit does not receive power Voltage indicator is
off.
1. Check the power connection.
2. Replace the controller/ repeater
3. Synchronize the system.
5 Valve is in an intermediate position Water valve indicator
is flashing
1. Close or open the valve if required.
2. Return to stage No. 2