Manual

Page 34
6.0 SPECIFICATIONS
6.1 Electrical Specifications
6.1.1 DC Voltage
Ranges: 0.6, 3, 15, 60, and 300 VDC.
Accuracy: ±1.5% of full scale 0 to 50 C.
±2.5% of full scale -40 to 85 C.
Sensitivity: 1000 ohms per volt.
Overload: Continuous: 20 VRMS or 5 times full
scale, whichever is greater, not to
exceed 600 VRMS.
Ten seconds: 30 VRMS or 10 times full
scale, whichever is greater, not to
exceed 700 VRMS.
6.1.2 DC milliAmps
Ranges: 15, 60, and 300 mADC.
Accuracy: ±1.5% of full scale 0 to 50 C.
±2.0% of full scale -40 to 85 C.
Burden Volts: 60 mV nominal at full scale. Leads and
fuse add 250 milliohms typical resistance.
Overload: Fuse blows before damage.