Specification

Specifications
Cable Types Tested
Shielded and unshielded twisted pair
All cable categories Coax
All types Telephone, speaker and alarm wire
Cable Tests
Opens, shorts, reversals, split pairs, wiremap, propagation
delay,skew, ohms.
Feet and metricselectable
Advanced Cable Tests
Length and distance to fault
Adjustable and standard VOP settings for accurate length of all cables
RLQ (Return Loss Quality)
Locating cable ends, split wires and switch ports
Wall jack identifiers (RJ45, coax, and mixed kits available)
Speaker identification (Qty 8 available separately)
Port blink
LVPRO lights the LED on the port switch
Device Tests
Speakers: audible popper
Voltage Protection
DC Volts: 100V / AC Volts: 70
Length Measurement
Max (all wire types): 1000 feet (305m)
Min split pairs: 6 feet (2m)
Min RLQ: 20 feet (7m)
VOP calibration:Min cable sample 150 feet (50m)
Network Devices
10/100/1000 advertised speed and cable pairs used
PoE pairs and cable pairs used
CCTV camera video signal: measure peak to peak volts
CATV (cable TV) requires min 30mV peak to peak signal
Battery test:100mA loaded test for 12V alarm and other batteries
Printed Reports
Stores 250 cable test reports in memory
Battery
Type: 4 AA alkaline
Life: 24 to 30 hours
Auto power off: 30 minutes
Backlit Display
Off and 2 brightness levels
LVPRO20 LVPRO30 LVPRO30SR
√ √ √
√ √ √
√ √ √
√ √ √
√ √ √
√ √ √
√ √ √
√ √ √
√ √ √
850 Perimeter Road • Manchester, NH • (603) 669-6400 • info@triplett.com
LVPRO Series Multifunctional Low Voltage Cable/Network Testers