User Manual

13
CAT 5/6 UTP Cable Testing / RW CERTIFY / LEVEL 1
Follow the instructions. Only an uncoiled cable will give you accurate
test results. At this point in the testing, the far end of the cable should
not be connected to any device. Note: If the cable is connected to a
device you will be alerted to check the far end of the cable. When ready
to proceed, press the down arrow ( TEST).
Error Messages: If there is a problem that stops the test from proceed-
ing, one of the following error messages will be displayed:
CABLE IS ACTIVE: There is an active network port on the far end
of the cable. You will need to unplug it to proceed.
CHECK CABLE END: A voltage is present on one or more of the
cable pairs or the REMOTE PROBE is connected to the cable end
when it is not needed. You will need to unplug it to proceed.
NO CABLE: There is no cable connected or an inactive port is
plugged into the far end of the cable.
Note: If errors persist from test to test, please contact the factory.
UN-COIL CABLE
PLUG OPEN CABLE
INTO LEFT PLUG
DO NOT USE PROBE
EXIT TEST
Press down arrow
button after cable
is connected
CAT 5/6 UTP
RW CERTIFY UTP
Perform Real World
Certiļ¬ cation Level 1 (UTP
cables) and Level 2 (UTP
cables and LAN devices)