User Manual

CAT 5/6 UTP Cable Testing / RW CERTIFY / LEVEL 1
16
CAT 5/6 UTP
LEDs
PLUG IN PROBE AT
FAR END OF CABLE
<RED LED = DONE>
TRACE TONES ON
EXIT
The REMOTE PROBE is required for the WIRE MAP to be con-
structed. Plug the Remote Probe into the far end of the cable. Tracer
tones have been turned ON to help locate cables in crowded areas
(press the TRACE button on the Remote Probe and hold it close to
the cable to follow the tone). The Main Unit's wire map test is triggered
when the Remote Probe is connected to the far end of the cable
(there are no buttons to push). The wire map tests for correct cable
pairing. Note: The wire map is displayed during the Review process.
Not during the test.
Remote Probe LEDs. The Remote Probe
needs to be connected only for a brief period.
Flashing LED(s) indicate the test is progressing.
A steady LED indicates the test is completed.
This saves you an extra trip to retrieve the
probe. If LED(s) continue to fl ash the cable,
the cable has a wiring problem. Disconnect
the probe and go to the Main Unit to see
the see the results. Note: If you plan to test
to Real World Certifi cation Level 2, now is a
good time to plug in the hub, switch or PC (it
will save you a trip).
Testing is halted
until the Remote
Probe is connect-
ed.