User Manual

accurate length measurement. At this point in the testing, the far end
of the cable should not be connected to any device. Note: If the far end
of the cable is connected to any device it will notify you to check the far
end of the cable.When ready to proceed, press ( TEST).
Error Messages: If there is a problem that stops the test from proceed-
ing, one of the following error messages will be displayed:
CABLE IS ACTIVE: There is an active network port on the far end
of the cable. You will need to unplug it to proceed.
CHECK CABLE END: A voltage is present on one or more of the
cable pairs or the REMOTE PROBE is connected to the cable
end when it is not needed. You will need to unplug it to proceed.
NO CABLE: There is no cable connected or an inactive port is
plugged into the far end of the cable. Plug in the cable or discon-
nect the inactive port.
CAT 5/6 UTP Cable Testing / BASIC TEST UTP
31
CAT 5/6 UTP
Cable testing has commenced. You can follow its progress on the
display. During this phase of testing, information about length, opens,
shorts and split pairs is being gathered and computed. If any cabling
errors are encountered you will be alerted including the distance to
any problems..
TESTING CABLE
TEST FOR DATA
*SPLITS
12> 36> 45> 78>
TDR
Testing
progress
is
displayed