Datasheet

OverPower inverter output supports longer duration overloads to 150% for 1-60 minutes under ideal battery and temperature conditions.
3-stage, selectable wet/dry cell battery charger (30-amp high/7.5-amp low)
3-position operating mode switch supports "AUTO" mode to enable automatic transfer between DC and AC modes, CHARGE-ONLY to maintain a full
battery charge when AC is present without auto transfer and SYSTEM OFF settings
Set of six front panel LEDs display AC/DC operational modes, overload status, DC voltage level, shutdown status and system fault status
Set of 4 configuration dipswitches support wet/gel battery charging profiles, adjustable 259/264V high voltage auto transfer during overvoltages and
selectable 144/163/182/201V AC low voltage auto transfer during brownouts
Set of 4 additional configuration dip switches support 4 levels of charger limiting relative to output load size
Resettable 10A charger AC input breaker and resettable 15A AC output breaker and automatic 2 speed cooling fan protect the inverter from load and
temperature related failures
Automatic overload and thermal shutoff safely turns off inverter as excessive loads or overheating conditions develop
Front panel remote control connector enables remote off/on switching (requires APSRM4 switch accessory)
Specifications
General Info
RoHS Y
OVERVIEW
Style Heavy-duty with built-in battery charger
OUTPUT
Frequency Compatibility 50 Hz
Output Receptacles Hardwire
Output (Watts) 3600
Continuous Output Capacity (Watts) 3600
Peak Output Capacity (Watts) 7200
Output Nominal Voltage 230V
Output Voltage Regulation
LINE POWER (AC): Maintains 230V nominal sine wave output from line power source. INVERTER POWER (AC):
Maintains PWM sine wave output voltage of 230 VAC (+/-5%).
Output Frequency Regulation 50 Hz (+/- 0.3 Hz)
Overload Protection Includes 12A input breaker dedicated to the charging system and 20A output breaker for AC output loads.
INPUT
Nominal Input Voltage(s) Supported 230V AC
Recommended Electrical Service
DC INPUT: Requires 36VDC input source capable of delivering 114A for the required duration (when used at full
continuous capacity - DC requirements increase during OverPower and DoubleBoost operation). For automotive
applications, professional hardwire installation with 300A minimum battery system fusing is recommended.
2 / 4