200206215 93-2029 Internet Office Owner’s Manual.qxd 7/15/02 1:42 PM Page 1 Owner’s Manual Internet Office™ • BC Internet™ 120V Input/Output Standby UPS Systems UL 1778 Important Safety Instructions 2 Quick Installation 3 Basic Operation 4 Storage & Service 7 Specifications 8 Español 9 Français 19 1111 W. 35th Street Chicago, IL 60609 USA Customer Support: (773) 869-1234 • www.tripplite.com Copyright © 2002 Tripp Lite. All rights reserved.
00206215 93-2029 Internet Office Owner’s Manual.qxd 7/15/02 1:42 PM Page 2 Important Safety Instructions SAVE THESE INSTRUCTIONS This manual contains instructions and warnings that should be followed during the installation, operation and storage of all Tripp Lite UPS Systems. Failure to heed these warnings will void your warranty. UPS Location Warnings • Install your UPS indoors, away from excess moisture or heat, conductive contaminants, dust or direct sunlight.
200206215 93-2029 Internet Office Owner’s Manual.qxd Quick Installation 1 Connect your UPS to an electrical outlet. Your UPS will run a self-test after it is plugged in. See Basic Operation to understand the results of its self-test. 1 2 Plug your computer, monitor and external modem into UPS/Surge outlets. Plug other equipment into Surge-only outlet(s). Separate UPS/Surge and Surge-only outlet(s) are identified on the back of your UPS. Your UPS is designed to support only computer equipment.
200206215 93-2029 Internet Office Owner’s Manual.qxd Quick Installation 7/15/02 1:43 PM Page 4 optional These connections are optional. Your UPS will function properly without these connections. 1 Phone Line/Network Line Surge Suppression NORM DELAY Your UPS can protect your equipment against surges over a phone line. Select models have RJ45 jacks that can also be used to protect against surges over a network data line (see Specifications).
200206215 93-2029 Internet Office Owner’s Manual.qxd Basic Operation 7/15/02 1:43 PM Page 5 continued Cold-Start Your UPS: You may “cold start” your UPS and use it as a stand-alone power source when utility power is not present, providing that the UPS battery is charged. To “cold start” your UPS, press and hold the ON/OFF button until you hear a beep (about 2 seconds), then release it.
200206215 93-2029 Internet Office Owner’s Manual.qxd Basic Operation Indicator Lights 7/15/02 1:43 PM Page 6 continued continued BATTERY CHARGE: This red light will turn ON continuously after the UPS runs a self-test to indicate that the UPS’s battery is weakly charged. If it remains lit after you have allowed the UPS to charge for twelve hours and run a second self-test, contact Tripp Lite for service.
200206215 93-2029 Internet Office Owner’s Manual.qxd Basic Operation Other UPS Features NORM DELAY 7/15/02 1:43 PM Page 7 continued continued Power Sensitivity Adjustment: This dial is normally set fully counterclockwise, which enables the UPS to protect against waveform distortions in its AC input. When such distortion occurs, the UPS will normally switch to providing PWM sine wave power from its battery reserves for as long as the distortion is present.
200206215 93-2029 Internet Office Owner’s Manual.qxd 7/15/02 1:43 PM Page 8 Specifications Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice.