Specification Sheet

OUTPUT
Output Volt Amp Capacity (VA) 1500
Output kVA Capacity (kVA) 1.5
Output Watt Capacity (Watts) 900
Nominal Output Voltage(s)
Supported
110V; 115V; 120V
Nominal Voltage Details 120v nominal output in battery mode
Frequency Compatibility 50 / 60 Hz
Frequency Compatibility Details Automatic frequency selection
Output Voltage Regulation (Line
Mode)
-10%, +6%
Output Voltage Regulation (Battery
Mode)
+/- 5%
Output Receptacles (10) 5-15R
UPS Output Receptacles (Surge
Suppression Only)
5 UPS outlets, 5 surge-only outlets
Output AC Waveform (AC Mode) Sine wave
Output AC Waveform (Battery
Mode)
PWM sine wave
INPUT
Rated input current (Maximum Load) 12A
Nominal Input Voltage(s) Supported 120V AC
UPS Input Connection Type 5-15P
Input Circuit Breakers 20A
UPS Input Cord Length (ft.) 6
UPS Input Cord Length (m) 1.8
Recommended Electrical Service 15A 120V
Input Phase Single-Phase
BATTERY
Half Load Runtime (min.) 10 minutes (450 watts)
DC System Voltage (VDC) 24
Battery Recharge Rate (Included
Batteries)
Less than 8 hours from 10% to 90%
Internal UPS Replacement Battery
Cartridge
&nbsp;<a class="productLink" href="//www.tripplite.com/UPS-Replacement-Battery-Cartridge-Tripp-Lite-APC-Belkin-
Best-Powerware-Liebert-other-UPS~RBC51">RBC51</a>&nbsp;(requires 2)
Expandable Runtime No
3 / 6