Use and Care Manual

5
ADDITIONAL DISPLAY ITEMS
BATTERY INDICATORSOPERATING MODE INDICATORS
TEST
MUTE
1
2
3
4
5
10
9
7
6
8
11
LCD Display
The LCD Display indicates a variety of UPS
modes and operating conditions. To view
the various screens, press the
button
while the UPS is operating in line or battery
power mode.
The LCD DISPLAY is shown here fully
illuminated to identify all available icons
and labels. This is for explanation only—
there are no operating modes where the
screenisfullyilluminatedlikethisexceptfor
afewsecondsastheUPSisrstpluggedin.
5. BATTERY CHARGE METER continuously reports battery charge level.
6. LOAD LEVEL METER continuously reports load-level on UPS supported outlets.
7. OVERLOAD ICON comes on to report that UPS supported outlets are overloaded.
8. 3-DIGIT DISPLAY lights along with associated labeling and icons to report a variety of UPS
and site power related conditions.
9. 3-DIGIT DISPLAY SUFFIX display labels will selectively illuminate to describe the unit of
measurement the 3-digit display is currently reporting (V=volts, %=percent, A=amps,
kW=kilowatts,Hz=frequency,Min=minutes).
10. 3-DIGIT DISPLAY PREFIXES
•INPUTlightstoindicatethe3-digitdisplayisreportinganinputcondition(inputvoltage,
inputfrequency)
•OUTPUT lights to indicate the 3-digit display is reporting an output condition (output
voltage,outputHz,etc)
•BATTERYlightstoindicatethe3-digitdisplayisreportingabatteryrelatedcondition(battery
voltage)
•ESTIMATED RUNTIME lights to indicate that the 3-digit display is currently reporting
estimated runtime in minutes
11. FAULT ICON lights to indicate a variety of possible UPS fault conditions (see Error Messages
section for information on other reported faults)
1. ON-LINE MODE ICON indicates that AC
power is present and the UPS is running
from an input line power source.
2. AVR BUCK & AVR BOOST ICONS will
selectively illuminate during line power
mode to indicate Automatic Voltage
Regulation (AVR) is engaged. AVR”
& “BUCK” indicates an overvoltage
condition and output is reduced back to
usablelevels.AVR”&“BOOST”indicates
brownout/undervoltage conditions and
output is boosted back to usable levels.
3. ON BATT ICON indicates that the UPS
is running in battery mode, due to power
failureorsevereinputvoltageuctuation.
4. REPLACE BATTERY ICON will illuminate
to inform users that the UPS battery is
weakandrequiresreplacement.
Basic Operation continued
12-12-069-93-327C.indb 5 12/6/2012 9:28:35 AM