6 Connect a red test lead from the positive input of the multimeter to pin A
on the IFU power cable.
7 Read the measurement on the multimeter. Passing criteria is 46 Vdc to
56 Vdc.
8 Connect a black test lead from the negative input of the multimeter to
pin H on the IFU power cable.
9 Connect a red test lead from the positive input of the multimeter to pin B
on the IFU power cable.
10 Read the measurement on the multimeter. Passing criteria is 46 Vdc to
56 Vdc.
11 Set the 48 Vdc power source to OFF.
12 Connect 48 Vdc power cable to the power connector on the IFU as
illustrated in Figure 2-4.
DANGER HIGH CURRENT HAZARD: Do not turn
on power before reading the Triton Network Systems
product documentation. This device has a 48 Vdc
(4 amps operating peak per feed) direct current input.
DANGER LHASARD DU COURANT ÉLEVÉ : Ne
pas mettre la tension avant de lire la documentation du
produit fournie par la société Triton Network Systems. Cet
appareil a une alimentation directe de 48 V CC (courant
de pointe de 4 ampères par ligne dalimentation).
DANGER HIGH CURRENT HAZARD: Ensure that
the 48 Vdc power source is set to the OFF position
before beginning the installation procedures for the
Invisible Fiber Unit.
DANGER LHASARD DU COURANT ÉLEVÉ :
Sassurer que le bloc dalimentation 48 V CC est en
position HORS TENSION avant daborder les procédures
pour linstallation de lunité Invisible Fiber