To test the fiber optic cable:
1 Connect fiber optic test adapters to the IFU Alpha and IFU Beta fiber
cables.
Figure 3-11. Fast Ethernet Fiber Optic Continuity Test Setup
2 Carefully place the laser receiver IFU Beta test adapter (see Figure 3-11
and Table 3-7).
NOTE: Never connect the transmitter first.
3 Connect the transmitter to the IFU Alpha test adapter as called out in
Table 3-7.
4 Set the transmitter to 0 dBm continuous wave and 1310 nm.
5 Turn on both units and take readings at the receiver. Record the results in
Table A-3 on page A-2.
NOTE: The received signal should be stronger than 7.4 dBm (less
than 7.4 dB).